McAfee M-2750 - Network Security Platform Podręcznik Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
The required settings for HyperTerminal
are:
Baud rate: 38400 Stop Bits: 1
Number of Bits: 8 Control Flow: None
Parity: None
e
Plug the female end of a power cable into the power inlet and plug the other end into a power
source. The Sensor ships with standard US power and international cables.
The M-2750 does not have a power switch; you need to only plug the power cable into
a power source.
3 Cable the Monitoring ports
This procedure describes how to cable a Sensor to run in in-line mode.
a
Plug the cable appropriate for use with
your SFP module into one of the
Monitoring ports labeled xA (for
example, 1A).
McAfee supports only those SFP
modules purchased through
McAfee or from a
McAfee-approved vendor.
b
Plug another cable into the peer of the
port used in the earlier step. This port will be labeled xB (for example, 1B).
c
Connect the other end of each cable to the network devices that you want to monitor. (For
example, if you plan to monitor traffic between a switch and a router, connect the cable
connected to 1A to the router and the one connected to 1B to the switch.)
For instructions on how to cable the Sensor to run in other operating modes, see the
McAfee Network Security Platform Sensor Product Guide for your Sensor model.
4 Install the Manager Software
For detailed instructions, refer to McAfee Network Security Platform Installation Guide.
You must have administrator privileges on the target Windows server to install the Manager
software.
A MySQL database is included with the Manager and is installed (embedded) automatically
on your target Windows server during this process.
4
Przeglądanie stron 3
1 2 3 4 5 6 7 8 9 10 11 12

Komentarze do niniejszej Instrukcji

Brak uwag